Comprehensive comparison of traditional vs. advanced battery technologies

Thermal Runaway Temperature
High Risk
Traditional Lithium Ion
150°C (302°F)
Critical safety threshold exceeded at lower temperatures
Ultra Safe
SunFusion LiFePO4
270°C (518°F)
Superior thermal stability & safety margin
Chemical Stability
High Risk
Traditional Lithium Ion
Unstable Compound
Oxygen release during decomposition
Ultra Safe
SunFusion LiFePO4
Stable Compound
Strong Fe-P-O bonds prevent decomposition
Fire Safety Rating
High Risk
Traditional Lithium Ion
High Fire Risk
Prone to thermal runaway & propagation
Ultra Safe
SunFusion LiFePO4
4-Hour Fire Rating
Self-extinguishing properties
Isolated Battery Module Extra Protection
Environmental Impact
High Risk
Traditional Lithium Ion
Toxic Materials
Contains harmful cobalt & heavy metals
Ultra Safe
SunFusion LiFePO4
Eco-Friendly
100% recyclable materials

SunFusion Battery Solutions

Advanced Energy Storage Systems Comparison

ECHO 2.0

14.3 kWh
  • Configuration: 16-cell
  • Power Output: Up to 14 KW
  • Chemistry: LiFePO4
  • Fire Rating: 4-hour minimum
  • Battery Box: 5052-H32 Aerospace Aluminum
  • Temperature Resistance: 1,125-1,200°F

Advanced Safety Features

Multi-Layer Protection Systems & Safety Protocols

Battery Management System
Advanced Protection
  • Real-time cell monitoring
  • Temperature control system
  • Voltage balancing
  • Current protection
  • State of charge management
Fire Prevention System
Maximum Safety
  • Aerospace-grade aluminum enclosure
  • Thermal runaway prevention
  • Cell-level isolation
  • Multi-layer fire barriers
  • Heat dissipation technology
Emergency Systems
Rapid Response
  • Rapid shutdown capability
  • Emergency disconnect
  • Automatic fault detection
  • Alert notification system
  • Remote monitoring access
Safety Certifications
Fully Certified
  • UL 9540A certified
  • NFPA 855 compliant
  • CRC-R328.1 standards
  • IRC Section R328 approved
  • ETL listed

Warranty & Support Coverage

Industry-Leading Protection & Customer Care

Warranty Protection
25-Year Coverage
  • 25-year battery cell warranty
  • 10-year inverter warranty
  • Performance guarantee
  • Capacity retention warranty
  • Manufacturing defect coverage
Technical Support
24/7 Assistance
  • 24/7 emergency support
  • Remote system diagnostics
  • Certified technician network
  • Software updates & maintenance
  • Installation support

Installation Requirements

Professional Setup & System Integration

Installation Specifications

Location Requirements

  • Indoor or outdoor installation
  • Operating temperature:-4°F to 822°F (427°C)
  • Humidity: 5% to 95% non-condensing
  • Altitude: Up to 33,000 ft (10,000 m)
  • 1/8 in 5052-H32 aluminum ultimate tensile strength of 33,000 psi

Electrical Requirements

  • 48V connection
  • SunFusion Cabinet Installation
  • Perferred SunFusion System Installation
  • Dedicated circuit breaker
  • Client Wi-Fi

Clearance Requirements

  • Front access: 36 inches
  • Side clearance: .5 inches
  • Top clearance: .5 inches
  • Bottom clearance: .5 inches

Headquarters