SunFusion Energy Systems
Advanced Battery Safety & Technology Standards
Compliance: CRC-R328.1 | NFPA® 855 Chapter15 | IRC® Section R328
Battery Technology Safety Analysis
Comprehensive comparison of traditional vs. advanced battery technologies
Thermal Runaway Temperature
High Risk
Traditional Lithium Ion
150°C (302°F)
Critical safety threshold exceeded at lower temperatures
Ultra Safe
SunFusion LiFePO4
270°C (518°F)
Superior thermal stability & safety margin
Chemical Stability
High Risk
Traditional Lithium Ion
Unstable Compound
Oxygen release during decomposition
Ultra Safe
SunFusion LiFePO4
Stable Compound
Strong Fe-P-O bonds prevent decomposition
Fire Safety Rating
High Risk
Traditional Lithium Ion
High Fire Risk
Prone to thermal runaway & propagation
Ultra Safe
SunFusion LiFePO4
4-Hour Fire Rating
Self-extinguishing properties
Isolated Battery Module Extra Protection
Environmental Impact
High Risk
Traditional Lithium Ion
Toxic Materials
Contains harmful cobalt & heavy metals
Ultra Safe
SunFusion LiFePO4
Eco-Friendly
100% recyclable materials
SunFusion Battery Solutions
Advanced Energy Storage Systems Comparison
ECHO 2.0
14.3 kWh- Configuration: 16-cell
- Power Output: Up to 14 KW
- Chemistry: LiFePO4
- Fire Rating: 4-hour minimum
- Battery Box: 5052-H32 Aerospace Aluminum
- Temperature Resistance: 1,125-1,200°F
New
ECHO 3.0
16 kWh- Configuration: Enhanced 16-cell
- Power Output: Up to 16 KW
- Chemistry: Advanced LiFePO4
- Comms: Worldwide Monitoring of Each Cell Via Wi-Fi
- Fire Rating: 8-hour minimum
- Battery Box: 5052-H32 Aerospace Aluminum
- Temperature Resistance: 1,125-1,200°F
Advanced Safety Features
Multi-Layer Protection Systems & Safety Protocols
Battery Management System
Advanced Protection
- Real-time cell monitoring
- Temperature control system
- Voltage balancing
- Current protection
- State of charge management
Fire Prevention System
Maximum Safety
- Aerospace-grade aluminum enclosure
- Thermal runaway prevention
- Cell-level isolation
- Multi-layer fire barriers
- Heat dissipation technology
Emergency Systems
Rapid Response
- Rapid shutdown capability
- Emergency disconnect
- Automatic fault detection
- Alert notification system
- Remote monitoring access
Safety Certifications
Fully Certified
- UL 9540A certified
- NFPA 855 compliant
- CRC-R328.1 standards
- IRC Section R328 approved
- ETL listed
Warranty & Support Coverage
Industry-Leading Protection & Customer Care
Warranty Protection
25-Year Coverage
- 25-year battery cell warranty
- 10-year inverter warranty
- Performance guarantee
- Capacity retention warranty
- Manufacturing defect coverage
Technical Support
24/7 Assistance
- 24/7 emergency support
- Remote system diagnostics
- Certified technician network
- Software updates & maintenance
- Installation support
Installation Requirements
Professional Setup & System Integration
Installation Specifications
Location Requirements
- Indoor or outdoor installation
- Operating temperature:-4°F to 822°F (427°C)
- Humidity: 5% to 95% non-condensing
- Altitude: Up to 33,000 ft (10,000 m)
- 1/8 in 5052-H32 aluminum ultimate tensile strength of 33,000 psi
Electrical Requirements
- 48V connection
- SunFusion Cabinet Installation
- Perferred SunFusion System Installation
- Dedicated circuit breaker
- Client Wi-Fi
Clearance Requirements
- Front access: 36 inches
- Side clearance: .5 inches
- Top clearance: .5 inches
- Bottom clearance: .5 inches
Headquarters
9020 Kenamar Drive Suite 204
San Diego, CA 92121
Contact
Phone: 800.544.0282
Email: info@sunfusion.us